SO2 Analyser
Serinus 50 SO2 analyser
The new Serinus 50 SO2 analyser is the next generation in gas monitoring technology.
|
 |
The Serinus 50 SO2 analyser uses proven fluorescence detection technology to measure SO2 in ambient air (LDL <0.3ppb, Range 0-20ppm). Combining several new technical advances and innovative features, the Serinus delivers Ecotech's renowned performance and excellent value.
The Serinus 50 SO2 analyser is designed with modern technology and contains advanced communications for use in remote communication and instantaneous data display on the internet.
- U.S. EPA approval (EQSA–0809–188) with EN approvals (pending)
- More affordable to purchase, operate and maintain
- New zero volume fittings and flexible Teflon tubing improves system integrity
- New intuitive menu system with quick menu
- Internal memory stores 8 years of data
- Reduced power usage, lower carbon footprint
- Improved remote instrument diagnostics and maintenance functions
- New dual particulate filter can reduce scheduled maintenance calls by up to 50%
EC9850 SO2 analyser
The EC9850 SO2 analyser is Ecotech's original SO2 analyser with 20 years active use within the market.
|
 |
The EC9850A SO2 analyser combines microprocessor control with fluorescence detection to provide accurate measurements of SO2 in the range of 0-20 ppm with a detection limit of <0.3 ppb.
The EC9850 SO2 analyser is most suited to applications that require internal zero/span or for those with previous 9800 series SO2 analysers.
- U.S. EPA approved (EQOA-0193-092)
- Internal pump option available
- Internal zero and span available
- Optional internal 12VDC power supply enables the SO2 analyzer to be operated from a battery or solar powered source for remote or mobile applications.
- External remote control of the SO2 analyser (provides up to 100 channels of instrument operating parameters)
- Data accessed via RS232, USB interface or optional Ethernet connector
Serinus 50 SO2 analyser
|
Range:
LDL:
Noise:
Temperature range:
Sample flow rate:
Weight:
Dimensions:
Power:
|
0-20 ppm
< 0.3 ppb with Kalman filter active
< 0.15 ppb with Kalman filter active
0 to 40°C
600 cc/min (optional 750cc/min)
18.1 kg (bench)
13.1 kg (rack)
440 x 178 x 620 mm (w x h x d), 3.5 RU
99-132 VAC, 198-264 VAC 47-63 Hz
|
Data Logging:
- Removable USB flash memory that stores data in the following formats:
- Instantaneous data from: 1, 3, 5, 10, 30, or 60 minute intervals
- Average data from: 1, 3, 5, 10, 15, 30 minutes, 1, 4, 8, 12, or 24 hours
- Data storage of 8 years, 1 minute data on 1 gigabyte memory
EC9850 SO2 analyser
|
Range:
LDL:
Noise:
Temperature range:
Sample flow rate:
Weight:
Dimensions:
Power:
|
0-20 ppm
0.5 ppb with Kalman filter active
0.25 ppb with Kalman filter active
5 to 40oC
500 cc/min
25 kg (A series)
24.8kg (B series)
440 x 178 x 620 mm (w x h x d), 3.5 RU
99-132 VAC, 198-264 VAC 47-63 Hz 110 Watts
|
Data Logging:
- Supports internal data logging capability with storage up to 175 days of 5 minute data stored in flash ROM
Serinus 50 SO2 analyser
|
Accessories
|
Pt No.
|
| Rack mount kit assembly (19”) |
E020102 |
| Internal low power pump (Max 6 watts) |
E020106 |
| External PUMP 230/240 VAC/50Hz |
P030004 |
| External PUMP 110/115 VAC/60 Hz |
P030005 |
| Dual sample filter (installed) |
E020100 |
|
Spares/Consumables
|
Pt No.
|
| Lamp Assembly UV |
C020076 |
| Dessicant, 5 gram pack (2 required) |
26000260 |
| Particulate filter (50 pce) |
98000098-1 |
| Annual Maintenance Kit |
E020204 |
| Scrubber assembly charcoal for zero air |
H010038 |
| Gasket, pressure sensor |
H010037 |
| Extraction tool orifice and filter |
98000190 |
EC9850 SO2 analyser
EC9850 SO2 analyser is available in two versions A series with internal pump, or B series without.
A series
| Instrument description |
Pt No. |
| EC9850A SO2 analyser with internal pump |
98501000-100 |
| EC9850A SO2 analyser, with internal pump & EZS |
98507000-3 |
| EC9850A SO2 analyser, customised version |
98501000-X |
B series
| Instrument description |
Pt No. |
| EC9850B SO2 analyser |
98507000-1 |
| EC9850B SO2 analyser with particulate filter |
98501000-3 |
| EC9850B SO2 analyser with particulate filter, EZS |
98507000-4 |
| EC9850B SO2 analyser with EZS |
98507000-5 |
| EC9850B SO2 analyser with particulate filter, span port mod |
98507000-6 |
| EC9850B SO2 analyser customised version |
98507000-X |
| EC9850B SO2 analyser with IZS |
98507000-2 |
^ A series only * B series only
|
Accessories
|
Pt No.
|
| Rack mount kit assembly (19”) |
9800036-2 |
| External zero/span valve assembly (EZS) |
98000087 |
| USB/Network Adaptor Assembly RJ45 option |
98007509-1 |
| 12 VDC Internal Power Supply |
98000115^ |
| Sample particulate filter assembly |
98000210-1* |
| External sample pump 115V 60 Hz |
P030005* |
| External sample pump 220V 50/60 Hz |
P030004* |
| PCA 50 pin I/O |
CIR 2015 * |
^ A series only * B series only
|
Spares/Consumables
|
Pt No.
|
| DFU filter |
036-040180 |
| Desiccant bags (2 required) |
26000260 |
| Particulate filter (50 p.ce) |
98000098-1 |
| Annual Maintenance Kit |
98507000-kit1* |
| Annual Maintenance Kit |
98501000-kit1^ |
| Extraction tool orifice and filter |
98000190 |
| Charcoal Scruber Assembly, Exhaust air |
98415105-1* |
| UV lamp |
98500018 |
| Lens UV Filter |
002-035400 |