Ozone Analyser

Serinus 10 Ozone Analyser

The new Serinus 10 Ozone (O3) analyser is the next generation in gas monitoring technology.

Serinus 10 ozone analyzer

The Serinus 10 Ozone analyser uses proven non-dispersive ultraviolet (UV) absorption technology to measure Ozone (O3) in ambient air (LDL 0.5ppb, Range 0-20ppm). Combining several new technical advances and innovative features, the Serinus delivers Ecotech's renowned performance and excellent value.

 

The Serinus 10 Ozone analyser is designed with modern technology and contains advanced communications for use in remote communication and instantaneous data display on the internet.

  • U.S. EPA approval (EQOA80987) with EN approvals (pending)
  • More affordable to purchase, operate and maintain
  • New zero volume fittings and flexible Teflon tubing improves system integrity
  • New intuitive menu system with quick menu
  • New internal memory stores 8 years of data
  • Reduced power usage, lower carbon footprint
  • Improved remote instrument diagnostics and maintenance functions
  • New dual particulate filter can reduce scheduled maintenance calls by up to 50%


EC9810 Ozone analyser

The EC9810 Ozone analyzer is Ecotech's original ozone analyser with 20 years active use within the market.

The EC9810A Ozone analyser combines microprocessor control with ultraviolet (UV) photometry to provide accurate measurements of ozone in the range of 0-20 ppm with a detection limit of 0.5 ppb.

 

The EC9810 Ozone analyser is most suited to applications that require internal zero/span or for those with previous 9800 series ozone analyzers.

  • U.S. EPA approved (EQOA-0193-091)
  • Internal pump option available
  • Internal zero and span available
  • Optional internal 12VDC power supply enables the ozone analyser to be operated from a battery or solar powered source for remote or mobile applications.
  • External remote control of the ozone analyzer (provides up to 100 channels of instrument operating parameters)
  • Data accessed via RS232, USB interface or optional Ethernet connector

Serinus 10 Ozone analyser

Range:

LDL:

Noise:

Temperature range:

Sample flow rate:

Weight:

 

Dimensions:

Power:

0-20 ppm

< 0.5 ppb with Kalman filter active

< 0.25 ppb with Kalman filter active

0 to 40

500 cc/min (optional 750cc/min)

14.8 kg (bench)

9.8 kg (rack)

440 x 178 x 620 mm (w x h x d), 3.5 RU

99-132 VAC, 198-264 VAC 47-63 Hz

Data Logging:

  • Internal memory that stores data in the following formats:
  • Instantaneous data from: 1, 3, 5, 10, 30, or 60 minute intervals
    • Average data from: 1, 3, 5, 10, 15, 30 minutes, 1, 4, 8, 12, or 24 hours
    • Data storage of 8 years, 1 minute data on 1 gigabyte memory


EC9810 Ozone analyser

Range:

LDL:

Noise:

Temperature range:

Sample flow rate:

Weight:

 

Dimensions:

Power:

0-20 ppm

0.5 ppb with Kalman filter active

0.25 ppb with Kalman filter active

5 to 40oC

500 cc/min

21 kg (A series)

20.8kg (B series)

440 x 178 x 620 mm (w x h x d), 3.5 RU

99-132 VAC, 198-264 VAC 47-63 Hz 110 Watts

Data Logging:

  • Supports internal data logging capability with storage up to 175 days of 5 minute data stored in flash ROM

Serinus 10 Ozone analyser

 

Accessories

Pt No.

Rack mount kit assembly (19”) E020102
Internal low power pump (Max 6 watts) E020105
External PUMP 230/240 VAC/50Hz P030004
External PUMP 110/115 VAC/60 Hz P030005
Dual sample filter (installed) E020100

 

 

 

Spares/Consumables

Pt No.

UV Lamp C020077
O3 scrubber 881-025001
Particulate filter (50 p.ce) 98000098-1
Annual Maintenance Kit E020201
Reaction cell tube 881-050900
Gasket, pressure sensor H010037
Extraction tool orifice and filter 98000190

 

 

EC9810 Ozone analyser


EC9810 ozone analyzer is available in two versions A series with internal pump, or B series without.

 

A series

Instrument description Pt No.
EC9810B Ozone analyser w/ IZS (enables 5 point O3 span) 98107000-2
EC9810B Ozone analyser, particulate filter 98107000-3
EC9810B Ozone analyser, particulate filter & EZS 98107000-4
EC9810B Ozone analyser, with EZS 98107000-5

 

B series

Instrument description Pt No.
EC9810A Ozone analyser with internal pump and EZS 98101000-5
EC9810A Ozone analyser with internal pump (Customised) 98101000-X

 

* B series only

Accessories

Pt No.

Rack mount kit assembly (19”) 9800036-2
External zero/span valve assembly (EZS) 98000087
USB/Network Adaptor Assembly RJ45 option 98007509-1
12 VDC Internal Power Supply 98000115
Sample particulate filter assembly 98000210-1*
External sample pump 115V 60 Hz P030005*
External sample pump 220V 50/60 Hz P030004*
PCA 50 pin I/O CIR 2015 *

 

 

^ A series only * B series only

Spares/Consumables

Pt No.

UV Lamp 98100011
O3 scrubber 881-025001
Particulate filter (50 p.ce) 98000098-1
Annual Maintenance Kit 98101000-kit1^
Annual Maintenance Kit 98107000-kit1*
Reaction cell tube 881-050900